Asce 7-10 Chapter 30

NEW ASCE 7 Hazard Tool identifies hurricane-prone regions and wind-borne debris regions, as defined in ASCE 7-16, Chapter 26 and ASCE 7-10. Serviceability wind speeds now returned with site wind speed; Seismic data expanded to include 14 coefficients, the seismic design category, and both horizontal and vertical response spectra. ASCE 7‐10 Wind Webinar Series. Example Problems Part 1 ‐Low‐Rise Buildings Part 2 ‐Low‐Rise Buildings (Simplified).

  1. Asce 7-10 Wind Loads Chapter 30 Pdf
  2. Asce 7-10 Chapter 30
  3. Asce 7-10 Chapter 30 Pdf
  • From site-specific procedures (Chapter 21) of. ASCE 7-10 & 2009 NEHRP Provisions. 30 ° N 35 ° N 40 ° N 45 °.
  • Chapter 31 - Wind tunnel procedure. Basic wind speed: (for strength design) ASCE 7-10 removes important factor Iw from wind load equation from ASCE 7-05 and replaces it with three different wind maps. Basic wind speed in U.S. Is shown in wind hazard map: Figure 26.5-1A.
  • I am designing a building per Ch. 30 part 2 of ASCE 7-10. I have the MWFRS pressures and the component and cladding (C&C) pressures for the walls and the roof taken directly for Fig. I'm struggling a little with the roof overhang C&C pressures. My building requires a basic wind speed of 120 mph.

Wind load calculation

Basics in ASCE 7-10

ASCE 7-10 change wind load calculaltion from service design wind load to strength design wind load.

ACSCE 7-10 covers wind load from chapter 26 to 31 as follows:

  • Chapter 26 - General requirements - It includes three wind maps for categories I, II, III and IV. for basic wind speed, V, wind directionality factor, Kd, exposure categories and constants, topographic effects (Kzt), gust response factor, G, enclosure classification, and internal coefficient (GCpi), etc.

  • Chapter 27: Wind load on Buildings - MWFRS (directional procedure) - Part 1: Wind load on building for all height - it includes velocity pressure equation, design wind pressure equation , parapmeter, Kz, Kh, Cp, CN, Part 2: Wind load on simple diaphragm with h = or <160 ft - includes wind pressure tables for exposure B, C, and D.

  • Chapter 28 - Wind load on Buildings - MWRFS (Envelope Procedure) - Part 1: Wind pressure on low rise building with windward, leeward, and side walls pressure. Part 2: Simplified design wind pressure tables for low-rise enclosed buildings.

  • Chapter 29 - Wind loads on other structures and building appurtenances - MWFRS - Wind pressure calculations for signs, chimneys, tanks, roof top equipment, lattice frameworks, trussed towers.

  • Chapter 30 - Components and Cladding (C & C) - Part 1: Low-rise buildings. Part 2: Low-rise building (simplified). Part 3: Building with h > 60 ft. Part 4: building with h = or < 160 ft. Part 5: Opening buildings. Part 6: building appurtenances, rooftop structures and equipments.

  • Chapter 31 - Wind tunnel procedure

Chapter 26

Basic wind speed: (for strength design)

ASCE 7-10 removes important factor Iw from wind load equation from ASCE 7-05 and replaces it with three different wind maps.

Ashampoo winoptimizer free key. Basic wind speed in U.S. is shown in wind hazard map:

Figure 26.5-1A. - Basic wind speeds for Occupancy Category II building and other structures Business in a box zip.

Figure 26.5-1B - Basic wind speeds for Occupancy Category III and IV buildings and Other Structures

Figure 26.5-1C - Basic wind speeds for Occupancy Category III and IV buildings and Other Structures

7-10

The basic wind speed is basic on statistical data collected from airport across U.S.The wind speeds correspond to 3-second gust speeds at 33 ft above ground for exposure C category.The wind speeds represent 50-year return period.

Wind hazard map can be found on IBC website Chapter 16, section 1609.

Exposure to wind:

A distinction was made surface roughness categories and exposure categories.Interpolation between exposure categories is permitted by rational analysis.Wind is to be evaluated in the worst case of the two 45-degree sectors either side of the wind direction.

Surface roughness categories:

  • Surface roughness B: Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger.
  • Surface roughness C: Open terrain with scattered obstructions having heights generally less than 30 ft. including flat open country, grasslands, and all water surfaces in hurricane-prone regions.
  • Surface roughness D: Flat, unobstructed areas and water surfaces outside hurricane-prone regions including smooth mud flats, salt flats, and unbroken ice.

Exposure categories:

Asce
  • Exposure B: Surface roughness B in upwind direction for 2630 ft or 10 times the height of the buildings.For buildings with mean roof height 30 ft or less, the upwind distance is reduced to 1500 ft.
  • Exposure C: apply to all cases not in B or D.
  • Exposure D: Surface roughness D in upwind direction for 500 ft or 10 times the height of the buildings.Expose D shall extend inland from the shoreline for a distance of 600 ft or 10 times the height of the building.

Note: This also allow the building to be designed in different exposure in different direction.A building located at edge of city or sea shore may be designed for exposure category in one direction and other exposure in other direction.

Building classifications

Building enclosure and openings and protection:

Open building: A building having each wall at least 80% open.

Partially enclosed building: building that meet the following conditions; Office 2016 mac uninstall completely.

  1. Ao> 1.10Aoi
  2. Ao> 4 ft2or 0.1 Agand Aoi/Agi£0.2

Ao= total area of openings in a wall the received positive pressure

Ag= the gross area of wall in the same wall of Ao.

Aoi= the sum of area in the building envelop not including Ao.

Agi= the sum of gross area of building envelop not including Ag.

Examples of partially enclosed buildings: Airplane hangars.One side of the building has door opening that larger than other 3 sides.

Asce 7-10 Wind Loads Chapter 30 Pdf

Enclosed buildings: buildings not qualified for open or partially enclosed.

2

Description


This sheet will generate the component and cladding pressures for each zone and 4 effective wind areas according to ASCE 7-10; Chapter 30 Part 2: Low-Rise Buildings (Simplified)

Calculation Reference
ASCE 7-10
Wind Loads
Hurricane Resistant Design

Calculation Preview

27 Aug 2012
351.00 Kb
Asce 7-10 Chapter 30
1031
1.0
2

This download is for Registered Users Only.
Perhaps you need to login or register.
Asce 7-10 Chapter 30
×

Asce 7-10 Chapter 30

I do have XLC installed, please correct me, if I'm wrong, but I still have the same problem with 'NAME' instead of solutions.
This spread sheet is unusable due to error: 'NAME' in most cells, please correct to make it useful.
Sorry tried to enable macros but am not computer savvy. Still can't get rid of #NAME?
Thanks!!

Asce 7-10 Chapter 30 Pdf

This download requires the XLC addin to be installed. If it is not installed then you will definitely see #NAME? errors. The XLC addin contains custom functions and macros read more information here.
This sheet uses macros, are macros enabled?
CANT GET IT WORKING.
SOME CELLS SHOW 'NAME?'
I AM RUNNING EXCEL 2011 ON MAC VERSION 14.5.5
IOS HIGH SIERRA VERSION 10.13.5
PLEASE CLARIFY.URGENT THANKS
ALAN
Thanks Tom I have extended your XLC Pro subscription by a further 3 months by way of thanks. [Admin]
This sheet will generate the component and cladding pressures for each zone and 4 effective wind areas according to ASCE 7-10; Chapter 30 Part 2: Low-Rise Buildings (Simplified)